Wireless parameters

project condition Typical value unit
Wireless parameters Frequency range 433/490 MHz
output power -9~+22dBm dBm
Output power adjustment step in dB steps 1 dB
Receive sensitivity -123dBm@1.2kbps@FSK dBm
Maximum input signal- dBm

Power Consumption

Ambient temperature: 25℃ Working voltage: 3.3V Working mode: LDO mode

project Operating mode Typical value unit
Current OFF mode (cold start 1) 160 nA
SLEEP mode (warm start 2) <1.2 μA
TX  @22dbm FSK 107 mA
RX  LoRa® 125 kHz 4.6 mA

Working conditions Operating Range

project parameter condition Minimum Typical value Max unit
VCC Power supply To the ground 1.8 3.3 3.7 V
VDD Power supply To the ground 1.8 3.3 3.7 V
TA Operating temperature -40 + 25 +85

Rated value Absolute Maximum Ratings

project parameter condition Minimum Typical value Max unit
VCC Power supply To the ground -0.5 3.3 3.9 V
VDD Power supply To the ground -0.5 3.3 3.9 V
TA Operating temperature -55 +25 +125

Please contact a solution expert to discuss your project and create a solution that meets your needs Consult now